标准规范下载简介
(冀)12S2 给水工程简介:
(冀)12S2 给水工程部分内容预览:
图1压力式温度计外形图
图2双金属温度计外形图
图3远传型压力表外形图
《电工术语 原电池和蓄电池 GB/T 2900.41-2008》压力表选型安装说明(四) 图集号 12S2 页次 83
发装配式钢板给水箱规格技术参数表s序公称箱体尺寸外形尺寸箱板厚度接管真径(IN)郭位多段基培依数本苑港水管BABLIB1箱底箱璃进水管出水管泾流hh2h31211(kg)1950800025002500813326182665+210915015080200100120360143989发校205500400925005627412126654310015015080200100120300153931216080002500300081332618316510015015080200100120300+1443892210700040002500713041212665321001501508022015012030051847442380800040002500813341212665310015015080220150120300215326+249090004000250091364121266531001501568022050120001024584725100800050002500813351242665n100150156802205012050028718626110800055002500813356272665510015015080220150120300357794271201000060092000101396127216252100150150802205012030045880228150100005000300010139512431655100150150802050120300113691482916080005000400081335124416821502002008022050403009289588301809000500040009136$12441685215020020080220504(3001032105323119095005000400096395124416852150200200802201504030011b36111023220010000500040001013951244168515020020080U8003611477说明:1.对高强糖瓷钢板给水箱的箱板厚度8,凡用3、4者,均为52.水箱重量未含型钢底架重量图集号12S2装配式钢板给水箱选用表(三页次98
型钢底架条基础平面图
装配式捷瓷钢板给水箱规格技术参数表
图集号 12S2 装配式喷塑钢板给水箱选用表 页次 106
发核组合式不锈钢肋板给水箱规格技术参数表公称萌体尺寸外形尺筋板厚度接管直径(D3)部位参数基瑞参数水筋重量号容积RL,B,Hi箱顶箱底避水管出水管滋流管淮水管1B,(kg)(m)1.210001000122012001200132021.5404050322201005001200500160校1.812001200122014001400132021.5405032220100600400600204国2.11500120012201700140013201.5404050322201006001400750240342. 6180012001220200014001320221.550So654022010060014009003324.018001400160020001600170021.550506540220100700160090034955设5.116001600200018001800210021.550506540.22010080018008005406200016002000220018002100221. 5656580502551088001800100035876.47.72400160020002600180021003656580502531088001800800630924002000200026002200210036565805025510810002200800T7289.6制1011.62410241020002610261021003656580502551081205261080049941113.52800241020003000261021006565805025510812052610935108017, 6300024002440320026002540332808010065260118120026001000146312图集号12S2组合式不锈钢肋板给水箱选用表(一页次118
组合式不锈钢肋板给水箱规格技术参数表
r国有频率/fn烧动频率 水泵机组功率(KW) 地面安装 楼层安装 <2.2 2.1 3. 5 2.2 ~3.7 2.1~2.5 3,5~5.0 >3.7 2. 5 5. 0
3.2.6.橡胶隔报垫的其技术性能见本图册193~194页, 3.3水泵减振(橡胶剪切隔振器)安装,JG橡胶剪切隔振器性能见本 图册200页 3.4水系减振(ZT、ZTA型阻尼弹簧减振器)安装,ZT、2T.1型阻 尼弹策减振器性能见本图册195~196页 3.5立式水泵机组减振采用ZD型弹簧隔振器时、其上端与水泵机 组底座和钢垫板用螺栓固定,其下端与混凝土地面用螺栓固定,混凝土 强度等级为C25 4.本图册水系安装尺寸根据相应产品样本编制,设计采用水泵机纟
图集号 12S2 水泵安装说明(二) 页次 126
AABD轴冷单级立式离心泵性能 图集号 12S2 参数及安装尺寸表(二) 页次 164
ZTA型阻尼弹簧减报器性能参数及外形尺寸表
1.外胶层2.内胶层3.管架素4.钢丝图5.法兰 XGD2型橡胶挠性接头(双球体)
发立式隔膜式气压给水设备组装尺寸表机维形式一罐一浆一堆三泵二罐二条二罐三泵三罐一东三蜡三家审维体型号SQL400SOL600SQL800SQL1000SQL1200SOL1400SQL1600SQL1800SOL2000SQL1500SQL1600SQL1600SOL1800SQL2000敏水泵型号DP25DP25DP32DPSODP50DPS0DPSODPSODPSODG65DG65DG80EG80IG80A40060080010001200140016001800200015001660160018002000校H14201720216524502790294130393242347829903039303932423478710910111012101370153516851845200516151685168518452005何138153985628568457405n7.0770850890990110512051370147011551205120513701470设3503503504001504004004904006:06506806806805:50550550600600700.7007.00700950950980980980何LI655755855.9751075117512751375147513251375139014901590L.2510510510546546546546546546750750780780780制L1744194421442365254628+0301431943920555864938103868310043DNI808080100100100100125125100100100125125D2505U508080100100125125100100100125125DN32532325050505050506565808080DN42532325059505050506565808080说明:1.尺寸A及日按罐体工作压力1.6MPa而定2.对于三采以上的组合,长向尺寸增加L2、宽肉尺寸不变3.随设备的更新代,安装尺寸如与实际有差异,应以实际尺寸为准立式隔膜式气压给水设备图集号1252组装尺寸表页次210
变频调速供水装置设计施工说明 图集号 12S2 (三) 夏次 214
变频调速供水装置设计施工说明 图集号 12S2 (四) 页次 215
变频调速供水装置设计施工说明 图集号 12S2 (五) 页次 216
5.4控制设各应显示电压、电流、额率、谐波等参量:显示管网进出 口压力设定值、实际值;显示电源、电机、水泵、水源的运行和故障 设备应具有对过压、欠压、短路、过流、缺相等故障进行报警和自动保 护的功能,对可恢复的故障应能自动或手动消除,恢复运行,应有消除 瞬间流量:压力波动过大的功能。 5.5管网叠压供水设备应有产品质量技术监督部门的质量检测报告 卫生监督部门的卫生许可批件。 5.6所选用的管网叠压供水设备应符合行业标准《管网叠压供水设.2 备》(CJ/T254)的规定, 6设备的布置安装 6.1要求环境温度宜为4~40℃,空气相对湿度<90%(温度为20℃±5~ 时),所在地海拔高度不超过1000m,设备间应有排水设施 6.2设备房应无导电或爆炸性尘埃,无府蚀性金属、无破坏绝缘的 气体或蒸汽. 6.3管网查压供水设备的进水管应单独接自供水于管,并宜从坏网 接入,进水管径宜比供水干管小两须及两级以上,或不大于供水干管过 水面积的1/3,也可按下表选用。
WWG系列供水设备(三台泵)平面图
JGJ∕T 251-2011 建筑钢结构防腐蚀技术规程WG系列供水设备(三台泵)侧面图
WWG系列供水设备选型及安装尺寸表(一)
AKK型叠压给水设备(两台泵)平面图
2.设各的底座及基磅见本图册第256页设备外形、底座、基陷尺寸图。
2.设各的底座及基磅见本图册第256页设备外形、底座、基聪尺寸图。
HLXB系列箱式供水设备 图集号 12S2 安装图(一) 页次 254
CJ∕T 172-2002 电子式出租汽车计价器 微型击打式点阵打印机HLXB系列三泵组箱式供水设备性能参数、选型及安装尺寸表(三
配动:本表为部分没务配号:如销共象型号司房厂商瓷面